BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Events//NONSGML v1.0//EN
METHOD:PUBLISH
BEGIN:VEVENT
DTSTART;TZID="Pacific Time (US & Canada)":20201112T130000
DTEND;TZID="Pacific Time (US & Canada)":20201112T150000
SUMMARY:Mohammad Ghanaatian Jobzari &#8211; Doctoral Final Exam
LOCATION:Online
DESCRIPTION:Advisor:  Dr. Saeed Lotfifard\n\nDegree: Ph.D. Electrical &amp; Computer Engineering\n\nDissertation Title: MODELING AND MONITORING OF FAULTED POWER DISTRIBUTION SYSTEMS WITH INVERTER INTERFACED DISTRIBUTED GENERATORS\n\nAbstract:  This dissertation studies the regular faults and high impedance faults in power distribution systems with inverter interfaced distribution generators. Chapter one proposes a method for calculating short circuit current in distribution systems with Inverter Interfaced Distributed Generators (IIDG). It is capable of calculating the short circuit in a multi-phase distribution systems based on the symmetrical components without obtaining the complete impedance matrix. Furthermore, it considers the load effect and the pre-fault state of the system for the fault analysis and is able to handle unbalanced systems with mutually coupled phases. The problem is formulated as an iterative linear system calculation and is solved by Generalized Minimal Residual (GMRES) approach. The validity of the proposed algorithm is verified through the simulation of IEEE 13-node, 123-node, 478-node, 954-node and 1430-node distribution systems. Simulation results demonstrate the effectiveness of the proposed algorithm and the advantages of using GMRES method to calculate the short circuit current in a distribution system with IIDG.\n\nChapter two considers the high impedance faults. High impedance faults (HIF) generate low fault current that makes the fault detection task challenging. Moreover, non-fault events like capacitor switching may have relatively similar behavior as arcing faults which can confuse HIF detection methods. This dissertation proposes a multi-criteria high impedance fault detection method. The proposed method is based on the change in the amplitudes of harmonics and interharmonics of measured current signal, change in the roots of characteristics equation, damping factor value of appeared current harmonics and interharmonics, and the existence of interharmonics. To extract these features from the measured current, the Prony method is utilized. To evaluate the performance of the presented method, capacitor bank switching, power electronic loads, inrush current, load switching, and HIF are simulated. The simulation results demonstrate that the proposed method successfully detects high impedance faults and distinguishes them from other disturbances.
BEGIN:VALARM
ACTION:DISPLAY
DESCRIPTION:REMINDER
TRIGGER;RELATED=START:-PT00H15M00S
END:VALARM
END:VEVENT
END:VCALENDAR
